Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height980mm
With optical interfaceNo
Width1037mm
Depth561mm
Number of HW-interfaces parallel0
With control elementYes
Number of analogue outputs2
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of HW-interfaces other1
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of digital outputs1
Number of HW-interfaces industrial Ethernet1
Number of digital inputs8
Number of analogue inputs2
Supporting protocol for ASINo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
With PC connectionYes
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP00
Supporting protocol for SUCONETNo
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for INTERBUSNo
4-quadrant operation possibleNo
Supporting protocol for CANYes
Mains voltage380 - 500V
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Application in domestic- and commercial area permittedYes
Number of interfaces PROFINET0
Number of phases input3
Type of converterU converter
Integrated breaking resistanceNo
Application in industrial area permittedYes
Number of phases output3
Max. output frequency400Hz
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage315kW
Max. output at quadratic load at rated output voltage355kW
Nominal output current I2N590A
Supporting protocol for PROFIsafeNo
Relative symmetric net voltage tolerance10%
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IOYes
Max. output voltage500V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetYes
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34590FN-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

980mm

With optical interface

Width

1037mm

Depth

561mm

Number of HW-interfaces parallel

0

With control element

Number of analogue outputs

2

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces other

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of digital inputs

8

Number of analogue inputs

2

Supporting protocol for ASI

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

With PC connection

Supporting protocol for DeviceNet

Degree of protection (IP)

IP00

Supporting protocol for SUCONET

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Supporting protocol for INTERBUS

4-quadrant operation possible

Supporting protocol for CAN

Mains voltage

380 .. 500V

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Application in domestic- and commercial area permitted

Number of interfaces PROFINET

0

Number of phases input

3

Type of converter

U converter

Integrated breaking resistance

Application in industrial area permitted

Number of phases output

3

Max. output frequency

400Hz

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

315kW

Max. output at quadratic load at rated output voltage

355kW

Nominal output current I2N

590A

Supporting protocol for PROFIsafe

Relative symmetric net voltage tolerance

10%

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO

Max. output voltage

500V

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus