Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth561mm
Height1538mm
Width1037mm
Supporting protocol for LONNo
Number of analogue inputs2
Number of HW-interfaces industrial Ethernet1
Number of digital inputs8
Number of digital outputs1
Number of HW-interfaces RS-4851
With control elementYes
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Number of analogue outputs2
Number of HW-interfaces USB0
With optical interfaceNo
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPYes
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP00
Type of converterU converter
Application in industrial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
With PC connectionYes
Supporting protocol for SERCOSNo
Number of phases output3
Number of phases input3
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Mains voltage380 - 500V
Mains frequency50/60 Hz
Max. output at linear load at rated output voltage355kW
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage400kW
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes
Nominal output current I2N650A
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for BACnetYes
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34650FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

561mm

Height

1538mm

Width

1037mm

Supporting protocol for LON

Number of analogue inputs

2

Number of HW-interfaces industrial Ethernet

1

Number of digital inputs

8

Number of digital outputs

1

Number of HW-interfaces RS-485

1

With control element

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for CAN

Number of analogue outputs

2

Number of HW-interfaces USB

0

With optical interface

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Degree of protection (IP)

IP00

Type of converter

U converter

Application in industrial area permitted

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

With PC connection

Supporting protocol for SERCOS

Number of phases output

3

Number of phases input

3

Integrated breaking resistance

4-quadrant operation possible

Mains voltage

380 .. 500V

Mains frequency

50/60 Hz

Max. output at linear load at rated output voltage

355kW

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

400kW

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Nominal output current I2N

650A

Supporting protocol for PROFIsafe

Max. output voltage

500V

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Related products