Technical specifications

Width1037mm
Number of analogue inputs2
Number of digital outputs1
Depth561mm
Number of HW-interfaces parallel0
Number of digital inputs8
Number of HW-interfaces RS-4851
Height1538mm
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet1
With control elementYes
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of analogue outputs2
Number of HW-interfaces other1
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP00
Mains voltage380 - 500V
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
4-quadrant operation possibleYes
Integrated breaking resistanceYes
Number of phases output3
Type of converterU converter
Number of interfaces PROFINET0
Number of phases input3
Max. output at linear load at rated output voltage400kW
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage450kW
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Max. output frequency400Hz
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Nominal output current I2N730A
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Max. output voltage500V
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetYes
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34730FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

1037mm

Number of analogue inputs

2

Number of digital outputs

1

Depth

561mm

Number of HW-interfaces parallel

0

Number of digital inputs

8

Number of HW-interfaces RS-485

1

Height

1538mm

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

1

With control element

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of analogue outputs

2

Number of HW-interfaces other

1

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for KNX

With optical interface

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Degree of protection (IP)

IP00

Mains voltage

380 .. 500V

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Application in industrial area permitted

4-quadrant operation possible

Integrated breaking resistance

Number of phases output

3

Type of converter

U converter

Number of interfaces PROFINET

0

Number of phases input

3

Max. output at linear load at rated output voltage

400kW

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

450kW

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Max. output frequency

400Hz

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Nominal output current I2N

730A

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Max. output voltage

500V

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p