Technical specifications

Number of digital inputs8
With control elementYes
Width1037mm
Number of digital outputs1
Number of HW-interfaces industrial Ethernet1
Height980mm
Depth561mm
Supporting protocol for LONNo
Number of analogue outputs2
Number of analogue inputs2
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP00
4-quadrant operation possibleNo
With PC connectionYes
Mains voltage380 - 500V
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Number of phases output3
Type of converterU converter
Number of phases input3
Integrated breaking resistanceNo
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage500kW
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Max. output frequency400Hz
Max. output at linear load at rated output voltage450kW
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Degree of protection (NEMA)Other
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetYes
Nominal output current I2N820A
Supporting protocol for Foundation FieldbusNo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IOYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34820FN-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

8

With control element

Width

1037mm

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

1

Height

980mm

Depth

561mm

Supporting protocol for LON

Number of analogue outputs

2

Number of analogue inputs

2

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Supporting protocol for ASI

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Degree of protection (IP)

IP00

4-quadrant operation possible

With PC connection

Mains voltage

380 .. 500V

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Number of phases output

3

Type of converter

U converter

Number of phases input

3

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

500kW

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Max. output frequency

400Hz

Max. output at linear load at rated output voltage

450kW

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Application in domestic- and commercial area permitted

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

820A

Supporting protocol for Foundation Fieldbus

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Related products