Technical specifications

Width1037mm
Height1538mm
With control elementYes
Number of HW-interfaces other1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Supporting protocol for PROFIBUSYes
Number of analogue outputs2
Supporting protocol for TCP/IPYes
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Number of analogue inputs2
Number of HW-interfaces RS-4851
Number of digital outputs1
Supporting protocol for ModbusYes
Supporting protocol for LONNo
Number of digital inputs8
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Depth561mm
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for DeviceNetYes
Number of interfaces PROFINET0
Integrated breaking resistanceYes
With PC connectionYes
Supporting protocol for SUCONETNo
Mains voltage380 - 500V
Mains frequency50/60 Hz
Max. output frequency400Hz
Number of phases input3
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleYes
Supporting protocol for other bus systemsYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage500kW
Relative symmetric net voltage tolerance10%
Type of converterU converter
Max. output at quadratic load at rated output voltage560kW
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Degree of protection (IP)IP00
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
Number of phases output3
Supporting protocol for PROFINET IOYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Nominal output current I2N920A
Supporting protocol for BACnetYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34920FB-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

1037mm

Height

1538mm

With control element

Number of HW-interfaces other

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Supporting protocol for PROFIBUS

Number of analogue outputs

2

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Number of analogue inputs

2

Number of HW-interfaces RS-485

1

Number of digital outputs

1

Supporting protocol for Modbus

Supporting protocol for LON

Number of digital inputs

8

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for INTERBUS

Depth

561mm

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for DeviceNet

Number of interfaces PROFINET

0

Integrated breaking resistance

With PC connection

Supporting protocol for SUCONET

Mains voltage

380 .. 500V

Mains frequency

50/60 Hz

Max. output frequency

400Hz

Number of phases input

3

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

500kW

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Max. output at quadratic load at rated output voltage

560kW

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Degree of protection (IP)

IP00

Supporting protocol for SERCOS

Application in industrial area permitted

Number of phases output

3

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Max. output voltage

500V

Nominal output current I2N

920A

Supporting protocol for BACnet