Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Supporting protocol for LONNo
Width1037mm
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-2320
Number of analogue outputs2
Number of digital inputs8
Number of analogue inputs2
Height980mm
Number of digital outputs1
Number of HW-interfaces RS-4220
Depth561mm
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other1
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for INTERBUSNo
With PC connectionYes
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
With optical interfaceNo
Supporting protocol for ASINo
Degree of protection (IP)IP00
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for CANYes
4-quadrant operation possibleNo
Number of phases output3
Number of phases input3
Mains voltage380 - 500V
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Type of converterU converter
Integrated breaking resistanceNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage560kW
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage500kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for BACnetYes
Relative symmetric net frequency tolerance10%
Supporting protocol for PROFIsafeNo
Max. output frequency400Hz
Max. output voltage500V
Nominal output current I2N920A
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for AS-Interface Safety at WorkNo
Degree of protection (NEMA)Other
Supporting protocol for DeviceNet SafetyNo
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DG1-34920FN-C00C

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Supporting protocol for LON

Width

1037mm

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Number of digital inputs

8

Number of analogue inputs

2

Height

980mm

Number of digital outputs

1

Number of HW-interfaces RS-422

0

Depth

561mm

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Number of HW-interfaces other

1

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for INTERBUS

With PC connection

Supporting protocol for SERCOS

Supporting protocol for Modbus

With optical interface

Supporting protocol for ASI

Degree of protection (IP)

IP00

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for CAN

4-quadrant operation possible

Number of phases output

3

Number of phases input

3

Mains voltage

380 .. 500V

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Type of converter

U converter

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

560kW

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

500kW

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Relative symmetric net frequency tolerance

10%

Supporting protocol for PROFIsafe

Max. output frequency

400Hz

Max. output voltage

500V

Nominal output current I2N

920A

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Degree of protection (NEMA)

Other

Supporting protocol for DeviceNet Safety

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.