Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs4
Number of digital outputs0
Width109mm
Number of analogue inputs1
Depth180mm
Power consumption159W
Height220mm
With control elementNo
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
Number of HW-interfaces USB0
Supporting protocol for CANNo
Number of HW-interfaces RS-4220
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4851
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for LONNo
With PC connectionYes
Supporting protocol for other bus systemsNo
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for DeviceNetNo
Type of converterU converter
Mains frequency50/60 Hz
Number of phases input3
Mains voltage200 - 240V
Number of phases output3
4-quadrant operation possibleYes
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceYes
Max. output frequency400Hz
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for INTERBUS-SafetyNo
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Number of interfaces PROFINET0
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage4kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Max. output voltage240V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Nominal output current I2N11A
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32011EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

4

Number of digital outputs

0

Width

109mm

Number of analogue inputs

1

Depth

180mm

Power consumption

159W

Height

220mm

With control element

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

Number of HW-interfaces USB

0

Supporting protocol for CAN

Number of HW-interfaces RS-422

0

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for LON

With PC connection

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for DeviceNet

Type of converter

U converter

Mains frequency

50/60 Hz

Number of phases input

3

Mains voltage

200 .. 240V

Number of phases output

3

4-quadrant operation possible

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Max. output frequency

400Hz

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for INTERBUS-Safety

Application in domestic- and commercial area permitted

Application in industrial area permitted

Number of interfaces PROFINET

0

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

4kW

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Max. output voltage

240V

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Nominal output current I2N

11A

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.