Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Depth180mm
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces parallel0
Number of analogue outputs1
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Number of digital outputs0
Supporting protocol for LONNo
Power consumption159W
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Width109mm
Number of digital inputs4
Number of analogue inputs1
Height220mm
With optical interfaceNo
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
With PC connectionYes
4-quadrant operation possibleYes
Type of converterU converter
Number of interfaces PROFINET0
Supporting protocol for Data-HighwayNo
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Mains voltage200 - 240V
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsYes
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Degree of protection (IP)IP20
Number of phases input3
Max. output at linear load at rated output voltage2.2kW
Max. output at quadratic load at rated output voltage4kW
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceYes
Max. output frequency400Hz
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Max. output voltage240V
Supporting protocol for BACnetYes
Nominal output current I2N11A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32011NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Depth

180mm

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces parallel

0

Number of analogue outputs

1

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Number of digital outputs

0

Supporting protocol for LON

Power consumption

159W

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Width

109mm

Number of digital inputs

4

Number of analogue inputs

1

Height

220mm

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

With PC connection

4-quadrant operation possible

Type of converter

U converter

Number of interfaces PROFINET

0

Supporting protocol for Data-Highway

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Mains voltage

200 .. 240V

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Degree of protection (IP)

IP20

Number of phases input

3

Max. output at linear load at rated output voltage

2.2kW

Max. output at quadratic load at rated output voltage

4kW

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output frequency

400Hz

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Max. output voltage

240V

Supporting protocol for BACnet

Nominal output current I2N

11A

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.