Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height220mm
Width109mm
With control elementYes
Number of digital outputs0
Number of HW-interfaces RS-4851
Depth180mm
Supporting protocol for CANYes
Number of HW-interfaces industrial Ethernet1
Number of analogue inputs1
Power consumption242.7W
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Supporting protocol for PROFIBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces RS-4220
Supporting protocol for ModbusYes
With optical interfaceNo
Number of digital inputs4
Number of analogue outputs1
Supporting protocol for INTERBUSNo
Number of HW-interfaces other1
Number of HW-interfaces serial TTY0
Supporting protocol for LONNo
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Max. output at linear load at rated output voltage4kW
Application in industrial area permittedYes
4-quadrant operation possibleYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage5.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency400Hz
Supporting protocol for EtherNet/IPYes
With PC connectionYes
Degree of protection (IP)IP20
Type of converterU converter
Application in domestic- and commercial area permittedYes
Number of phases input3
Relative symmetric net voltage tolerance10%
Number of phases output3
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Mains frequency50/60 Hz
Supporting protocol for other bus systemsYes
Relative symmetric net frequency tolerance10%
Mains voltage200 - 240V
Supporting protocol for PROFINET CBANo
Max. output voltage240V
Nominal output current I2N17.5A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32017NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

220mm

Width

109mm

With control element

Number of digital outputs

0

Number of HW-interfaces RS-485

1

Depth

180mm

Supporting protocol for CAN

Number of HW-interfaces industrial Ethernet

1

Number of analogue inputs

1

Power consumption

242.7W

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

Supporting protocol for Modbus

With optical interface

Number of digital inputs

4

Number of analogue outputs

1

Supporting protocol for INTERBUS

Number of HW-interfaces other

1

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Max. output at linear load at rated output voltage

4kW

Application in industrial area permitted

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

5.5kW

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

400Hz

Supporting protocol for EtherNet/IP

With PC connection

Degree of protection (IP)

IP20

Type of converter

U converter

Application in domestic- and commercial area permitted

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Number of phases output

3

Number of interfaces PROFINET

0

Integrated breaking resistance

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

Relative symmetric net frequency tolerance

10%

Mains voltage

200 .. 240V

Supporting protocol for PROFINET CBA

Max. output voltage

240V

Nominal output current I2N

17.5A

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.