Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs1
Power consumption332.3W
Height260mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
With control elementNo
Number of HW-interfaces RS-4851
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of digital inputs4
Number of analogue outputs1
Width130mm
Depth180mm
Number of digital outputs0
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for CANNo
With PC connectionYes
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
Type of converterU converter
Supporting protocol for DeviceNetNo
Mains frequency50/60 Hz
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Number of phases output3
Application in industrial area permittedYes
Number of phases input3
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Integrated breaking resistanceYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output at quadratic load at rated output voltage7.5kW
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Nominal output current I2N25.3A
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetNo
Max. output voltage240V
Max. output at linear load at rated output voltage5.5kW
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32025EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

1

Power consumption

332.3W

Height

260mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

With control element

Number of HW-interfaces RS-485

1

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of digital inputs

4

Number of analogue outputs

1

Width

130mm

Depth

180mm

Number of digital outputs

0

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces other

0

Supporting protocol for CAN

With PC connection

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Number of interfaces PROFINET

0

4-quadrant operation possible

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Supporting protocol for KNX

Supporting protocol for other bus systems

Type of converter

U converter

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Number of phases output

3

Application in industrial area permitted

Number of phases input

3

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Integrated breaking resistance

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output at quadratic load at rated output voltage

7.5kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Nominal output current I2N

25.3A

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Max. output voltage

240V

Max. output at linear load at rated output voltage

5.5kW

Degree of protection (NEMA)

Other

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.