Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height300mm
With control elementNo
Width184mm
Power consumption618.2W
Number of digital inputs4
Number of analogue inputs1
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of digital outputs0
Number of HW-interfaces industrial Ethernet0
Depth195mm
Number of analogue outputs1
Number of HW-interfaces RS-4220
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP20
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Supporting protocol for CANNo
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
4-quadrant operation possibleYes
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Number of phases input3
Type of converterU converter
Number of phases output3
Integrated breaking resistanceYes
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage15kW
Max. output at linear load at rated output voltage11kW
Max. output frequency400Hz
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for DeviceNet SafetyNo
Nominal output current I2N48.3A
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Max. output voltage240V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32048NB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

300mm

With control element

Width

184mm

Power consumption

618.2W

Number of digital inputs

4

Number of analogue inputs

1

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of digital outputs

0

Number of HW-interfaces industrial Ethernet

0

Depth

195mm

Number of analogue outputs

1

Number of HW-interfaces RS-422

0

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Supporting protocol for other bus systems

Supporting protocol for SUCONET

With PC connection

Supporting protocol for Data-Highway

Degree of protection (IP)

IP20

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

4-quadrant operation possible

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Number of phases input

3

Type of converter

U converter

Number of phases output

3

Integrated breaking resistance

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

15kW

Max. output at linear load at rated output voltage

11kW

Max. output frequency

400Hz

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for DeviceNet Safety

Nominal output current I2N

48.3A

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Max. output voltage

240V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.