Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs4
With control elementYes
Depth195mm
Power consumption618.2W
Height300mm
Width184mm
Number of HW-interfaces RS-4851
Number of analogue inputs1
Number of HW-interfaces RS-4220
Number of digital outputs0
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Degree of protection (IP)IP20
Supporting protocol for TCP/IPYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Supporting protocol for ModbusYes
Max. output at linear load at rated output voltage11kW
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Number of phases input3
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Foundation FieldbusNo
Type of converterU converter
With PC connectionYes
Max. output at quadratic load at rated output voltage15kW
Integrated breaking resistanceYes
Relative symmetric net frequency tolerance10%
Mains voltage200 - 240V
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPYes
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Application in industrial area permittedYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Number of phases output3
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Max. output voltage240V
Degree of protection (NEMA)Other
Supporting protocol for BACnetYes
Nominal output current I2N48.3A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-32048NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

4

With control element

Depth

195mm

Power consumption

618.2W

Height

300mm

Width

184mm

Number of HW-interfaces RS-485

1

Number of analogue inputs

1

Number of HW-interfaces RS-422

0

Number of digital outputs

0

Number of HW-interfaces parallel

0

Supporting protocol for LON

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Supporting protocol for other bus systems

With optical interface

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Supporting protocol for Modbus

Max. output at linear load at rated output voltage

11kW

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Number of phases input

3

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Supporting protocol for Foundation Fieldbus

Type of converter

U converter

With PC connection

Max. output at quadratic load at rated output voltage

15kW

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Mains voltage

200 .. 240V

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

4-quadrant operation possible

Mains frequency

50/60 Hz

Application in industrial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Number of phases output

3

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Max. output voltage

240V

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Nominal output current I2N

48.3A