  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth180mm
Number of digital inputs4
Number of digital outputs0
Number of analogue inputs1
Power consumption85W
With control elementYes
Height152mm
Width72mm
Supporting protocol for LONNo
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4220
Supporting protocol for ASINo
Number of HW-interfaces RS-2320
Number of HW-interfaces other1
Number of HW-interfaces RS-4851
With PC connectionYes
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP20
Supporting protocol for CANYes
Supporting protocol for PROFIBUSYes
Supporting protocol for DeviceNetNo
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
With optical interfaceNo
Supporting protocol for INTERBUS-SafetyNo
Mains voltage200 - 240V
Supporting protocol for SUCONETNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Supporting protocol for ModbusYes
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Max. output frequency400Hz
Number of interfaces PROFINET0
Type of converterU converter
Number of phases output3
Integrated breaking resistanceYes
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Number of phases input3
Max. output at linear load at rated output voltage0.75kW
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage240V
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N4.8A
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for BACnetYes
Relative symmetric net voltage tolerance10%
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-324D8EB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

180mm

Number of digital inputs

4

Number of digital outputs

0

Number of analogue inputs

1

Power consumption

85W

With control element

Height

152mm

Width

72mm

Supporting protocol for LON

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces RS-422

0

Supporting protocol for ASI

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

1

Number of HW-interfaces RS-485

1

With PC connection

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Degree of protection (IP)

IP20

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

With optical interface

Supporting protocol for INTERBUS-Safety

Mains voltage

200 .. 240V

Supporting protocol for SUCONET

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Supporting protocol for Modbus

Mains frequency

50/60 Hz

4-quadrant operation possible

Max. output frequency

400Hz

Number of interfaces PROFINET

0

Type of converter

U converter

Number of phases output

3

Integrated breaking resistance

Application in industrial area permitted

Application in domestic- and commercial area permitted

Number of phases input

3

Max. output at linear load at rated output voltage

0.75kW

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

240V

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

4.8A

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for BACnet

Relative symmetric net voltage tolerance

10%