Technical specifications

Height152mm
Depth180mm
Width72mm
Power consumption85W
Number of analogue outputs1
Number of HW-interfaces USB0
With control elementNo
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of digital outputs0
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-4220
Number of digital inputs4
Number of analogue inputs1
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
4-quadrant operation possibleYes
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for other bus systemsNo
Number of phases output3
Number of phases input3
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
Supporting protocol for SUCONETNo
Integrated breaking resistanceYes
Mains frequency50/60 Hz
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Max. output frequency400Hz
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPNo
Degree of protection (IP)IP20
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Nominal output current I2N4.8A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Max. output voltage240V
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-324D8NB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

152mm

Depth

180mm

Width

72mm

Power consumption

85W

Number of analogue outputs

1

Number of HW-interfaces USB

0

With control element

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of digital outputs

0

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-422

0

Number of digital inputs

4

Number of analogue inputs

1

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

4-quadrant operation possible

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

With PC connection

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for other bus systems

Number of phases output

3

Number of phases input

3

Supporting protocol for SERCOS

Application in industrial area permitted

Supporting protocol for SUCONET

Integrated breaking resistance

Mains frequency

50/60 Hz

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Max. output frequency

400Hz

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Degree of protection (IP)

IP20

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Nominal output current I2N

4.8A

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Max. output voltage

240V

Supporting protocol for BACnet