Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption85W
Number of digital outputs0
Depth180mm
Number of digital inputs4
With control elementYes
Width72mm
Height152mm
Number of analogue inputs1
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces other1
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of HW-interfaces USB0
Supporting protocol for DeviceNetNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Mains frequency50/60 Hz
Mains voltage200 - 240V
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Application in industrial area permittedYes
Type of converterU converter
Number of phases output3
Number of phases input3
Integrated breaking resistanceYes
Max. output frequency400Hz
Max. output at quadratic load at rated output voltage1.1kW
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at linear load at rated output voltage0.75kW
Relative symmetric net frequency tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Nominal output current I2N4.8A
Supporting protocol for BACnetYes
Max. output voltage240V
Application in domestic- and commercial area permittedYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-324D8NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Power consumption

85W

Number of digital outputs

0

Depth

180mm

Number of digital inputs

4

With control element

Width

72mm

Height

152mm

Number of analogue inputs

1

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

1

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of HW-interfaces USB

0

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for Data-Highway

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

With PC connection

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

Mains voltage

200 .. 240V

Number of interfaces PROFINET

0

4-quadrant operation possible

Application in industrial area permitted

Type of converter

U converter

Number of phases output

3

Number of phases input

3

Integrated breaking resistance

Max. output frequency

400Hz

Max. output at quadratic load at rated output voltage

1.1kW

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Max. output at linear load at rated output voltage

0.75kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Nominal output current I2N

4.8A

Supporting protocol for BACnet

Max. output voltage

240V

Application in domestic- and commercial area permitted

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.