Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width72mm
Height152mm
With control elementNo
Depth180mm
Power consumption99W
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of digital outputs0
Number of analogue outputs1
Number of analogue inputs1
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of digital inputs4
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Number of HW-interfaces serial TTY0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces parallel0
Supporting protocol for CANNo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Mains voltage200 - 240V
Degree of protection (IP)IP20
With PC connectionYes
Type of converterU converter
Mains frequency50/60 Hz
Max. output at linear load at rated output voltage1.5kW
Max. output frequency400Hz
Number of phases input3
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceYes
Application in industrial area permittedYes
Number of phases output3
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage240V
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Nominal output current I2N7.8A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-327D8EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

72mm

Height

152mm

With control element

Depth

180mm

Power consumption

99W

Supporting protocol for LON

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

0

Number of analogue outputs

1

Number of analogue inputs

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of digital inputs

4

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for CAN

With optical interface

Supporting protocol for INTERBUS

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

4-quadrant operation possible

Mains voltage

200 .. 240V

Degree of protection (IP)

IP20

With PC connection

Type of converter

U converter

Mains frequency

50/60 Hz

Max. output at linear load at rated output voltage

1.5kW

Max. output frequency

400Hz

Number of phases input

3

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Application in industrial area permitted

Number of phases output

3

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Max. output voltage

240V

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

7.8A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.