Aleta.hr
Main Product Image

DM1-34012NB-S20S-EM

Code: 1872059

ManufacturerEaton (Moeller)
Catalog number3-5012-005A
Type
EAN code4015081980932

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height220mm
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of digital outputs0
Number of analogue inputs1
Power consumption203W
Number of HW-interfaces industrial Ethernet1
Number of digital inputs4
Width109mm
Number of analogue outputs1
Depth180mm
With control elementYes
Supporting protocol for ModbusYes
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces serial TTY0
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Supporting protocol for INTERBUSNo
Mains voltage380 - 500V
Degree of protection (IP)IP20
With optical interfaceNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for CANYes
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other1
Supporting protocol for SUCONETNo
Supporting protocol for BACnetYes
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage5.5kW
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Integrated breaking resistanceNo
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Application in industrial area permittedYes
Number of phases input3
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Max. output voltage500V
Nominal output current I2N12A
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Number of phases output3
Max. output frequency400Hz
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage7.5kW
Type of converterU converter
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-34012NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage switchgear and control gear (automation)
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

220mm

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of digital outputs

0

Number of analogue inputs

1

Power consumption

203W

Number of HW-interfaces industrial Ethernet

1

Number of digital inputs

4

Width

109mm

Number of analogue outputs

1

Depth

180mm

With control element

Supporting protocol for Modbus

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces serial TTY

0

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

4-quadrant operation possible

Supporting protocol for INTERBUS

Mains voltage

380 .. 500V

Degree of protection (IP)

IP20

With optical interface

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for other bus systems

With PC connection

Supporting protocol for CAN

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Number of HW-interfaces other

1

Supporting protocol for SUCONET

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

5.5kW

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SafetyBUS p

Application in industrial area permitted

Number of phases input

3

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Max. output voltage

500V

Nominal output current I2N

12A

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Number of phases output

3

Max. output frequency

400Hz

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

7.5kW

Type of converter

U converter

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.