Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width109mm
Height220mm
Number of analogue inputs1
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
Power consumption332.4W
Number of digital inputs4
With control elementNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4851
Number of digital outputs0
Depth180mm
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
With optical interfaceNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Application in industrial area permittedYes
Max. output frequency400Hz
Integrated breaking resistanceYes
Degree of protection (IP)IP20
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Number of phases output3
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Number of phases input3
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage11kW
Supporting protocol for other bus systemsNo
Type of converterU converter
Max. output at linear load at rated output voltage7.5kW
Mains voltage380 - 480V
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N16A
Max. output voltage500V
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-34016EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

109mm

Height

220mm

Number of analogue inputs

1

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

Power consumption

332.4W

Number of digital inputs

4

With control element

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

1

Number of digital outputs

0

Depth

180mm

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

With optical interface

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

With PC connection

Application in industrial area permitted

Max. output frequency

400Hz

Integrated breaking resistance

Degree of protection (IP)

IP20

4-quadrant operation possible

Supporting protocol for SERCOS

Number of phases output

3

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Number of phases input

3

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

11kW

Supporting protocol for other bus systems

Type of converter

U converter

Max. output at linear load at rated output voltage

7.5kW

Mains voltage

380 .. 480V

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Supporting protocol for SafetyBUS p

Nominal output current I2N

16A

Max. output voltage

500V

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.