Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width109mm
Depth180mm
Height220mm
Number of digital inputs4
Power consumption332.4W
With control elementNo
Number of HW-interfaces RS-4851
Number of digital outputs0
Number of analogue outputs1
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of analogue inputs1
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
With optical interfaceNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces industrial Ethernet0
Degree of protection (IP)IP20
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Number of phases input3
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Max. output at quadratic load at rated output voltage11kW
Number of interfaces PROFINET0
Type of converterU converter
With PC connectionYes
Mains voltage380 - 480V
Integrated breaking resistanceYes
Max. output frequency400Hz
4-quadrant operation possibleYes
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for EtherNet/IPNo
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage7.5kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N16A
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-34016NB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

109mm

Depth

180mm

Height

220mm

Number of digital inputs

4

Power consumption

332.4W

With control element

Number of HW-interfaces RS-485

1

Number of digital outputs

0

Number of analogue outputs

1

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of analogue inputs

1

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

With optical interface

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

0

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for CAN

Number of phases input

3

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Max. output at quadratic load at rated output voltage

11kW

Number of interfaces PROFINET

0

Type of converter

U converter

With PC connection

Mains voltage

380 .. 480V

Integrated breaking resistance

Max. output frequency

400Hz

4-quadrant operation possible

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for EtherNet/IP

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

7.5kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Nominal output current I2N

16A

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.