Depth180mm
Width109mm
Height220mm
Number of HW-interfaces RS-4220
Power consumption332.4W
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-2320
Supporting protocol for Data-HighwayNo
With optical interfaceNo
Number of digital inputs4
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Number of analogue outputs1
With control elementYes
Supporting protocol for ModbusYes
Number of analogue inputs1
Number of digital outputs0
Supporting protocol for DeviceNetNo
Supporting protocol for TCP/IPYes
Supporting protocol for CANYes
Number of HW-interfaces parallel0
Number of HW-interfaces other1
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet1
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Max. output at linear load at rated output voltage7.5kW
Max. output at quadratic load at rated output voltage11kW
Application in industrial area permittedYes
Relative symmetric net frequency tolerance10%
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Supporting protocol for other bus systemsYes
Max. output frequency400Hz
With PC connectionYes
Mains voltage380 - 480V
Supporting protocol for AS-Interface Safety at WorkNo
Type of converterU converter
Application in domestic- and commercial area permittedYes
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Integrated breaking resistanceYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Number of phases input3
4-quadrant operation possibleYes
Relative symmetric net voltage tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Degree of protection (NEMA)Other
Supporting protocol for BACnetYes
Nominal output current I2N16A
Supporting protocol for PROFINET CBANo
Max. output voltage500V
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-34016NB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

180mm

Width

109mm

Height

220mm

Number of HW-interfaces RS-422

0

Power consumption

332.4W

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-232

0

Supporting protocol for Data-Highway

With optical interface

Number of digital inputs

4

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of analogue outputs

1

With control element

Supporting protocol for Modbus

Number of analogue inputs

1

Number of digital outputs

0

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Number of HW-interfaces other

1

Supporting protocol for LON

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

1

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Max. output at linear load at rated output voltage

7.5kW

Max. output at quadratic load at rated output voltage

11kW

Application in industrial area permitted

Relative symmetric net frequency tolerance

10%

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Supporting protocol for other bus systems

Max. output frequency

400Hz

With PC connection

Mains voltage

380 .. 480V

Supporting protocol for AS-Interface Safety at Work

Type of converter

U converter

Application in domestic- and commercial area permitted

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Integrated breaking resistance

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Number of phases input

3

4-quadrant operation possible

Relative symmetric net voltage tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

Nominal output current I2N

16A

Supporting protocol for PROFINET CBA

Max. output voltage

500V

Supporting protocol for PROFIsafe