Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of digital inputs4
Number of analogue inputs1
With control elementNo
Number of HW-interfaces RS-4220
Depth180mm
Supporting protocol for LONNo
Power consumption65W
Number of digital outputs0
Number of HW-interfaces industrial Ethernet0
Height152mm
Number of HW-interfaces RS-2320
Number of analogue outputs1
Width72mm
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Number of phases output3
Supporting protocol for PROFIBUSNo
Supporting protocol for other bus systemsNo
Mains voltage380 - 480V
Supporting protocol for DeviceNetNo
Number of interfaces PROFINET0
Type of converterU converter
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
4-quadrant operation possibleYes
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Integrated breaking resistanceYes
Application in industrial area permittedYes
Number of phases input3
Application in domestic- and commercial area permittedYes
Max. output frequency400Hz
Max. output at quadratic load at rated output voltage1.5kW
Max. output at linear load at rated output voltage0.75kW
Relative symmetric net frequency tolerance10%
Supporting protocol for EtherNet/IPNo
Supporting protocol for BACnetNo
Relative symmetric net voltage tolerance10%
Max. output voltage500V
Nominal output current I2N2.2A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Degree of protection (NEMA)Other
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-342D2EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of digital inputs

4

Number of analogue inputs

1

With control element

Number of HW-interfaces RS-422

0

Depth

180mm

Supporting protocol for LON

Power consumption

65W

Number of digital outputs

0

Number of HW-interfaces industrial Ethernet

0

Height

152mm

Number of HW-interfaces RS-232

0

Number of analogue outputs

1

Width

72mm

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

With optical interface

Supporting protocol for CAN

Supporting protocol for ASI

Number of phases output

3

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Mains voltage

380 .. 480V

Supporting protocol for DeviceNet

Number of interfaces PROFINET

0

Type of converter

U converter

With PC connection

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for KNX

Supporting protocol for INTERBUS

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

4-quadrant operation possible

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Integrated breaking resistance

Application in industrial area permitted

Number of phases input

3

Application in domestic- and commercial area permitted

Max. output frequency

400Hz

Max. output at quadratic load at rated output voltage

1.5kW

Max. output at linear load at rated output voltage

0.75kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Relative symmetric net voltage tolerance

10%

Max. output voltage

500V

Nominal output current I2N

2.2A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

Other

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.