Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height152mm
Width72mm
Power consumption65W
With control elementNo
Number of digital inputs4
Number of digital outputs0
Depth180mm
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Number of analogue inputs1
Number of analogue outputs1
Number of HW-interfaces other0
Supporting protocol for LONNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
With PC connectionYes
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Mains frequency50/60 Hz
Type of converterU converter
Number of phases input3
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Mains voltage380 - 480V
Number of phases output3
4-quadrant operation possibleYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Relative symmetric net frequency tolerance10%
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Max. output frequency400Hz
Supporting protocol for Foundation FieldbusNo
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetNo
Nominal output current I2N2.2A
Max. output voltage500V
Degree of protection (NEMA)Other
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-342D2NB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

152mm

Width

72mm

Power consumption

65W

With control element

Number of digital inputs

4

Number of digital outputs

0

Depth

180mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

With optical interface

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Supporting protocol for TCP/IP

Number of analogue inputs

1

Number of analogue outputs

1

Number of HW-interfaces other

0

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for CAN

With PC connection

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Mains frequency

50/60 Hz

Type of converter

U converter

Number of phases input

3

Integrated breaking resistance

Number of interfaces PROFINET

0

Mains voltage

380 .. 480V

Number of phases output

3

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Max. output frequency

400Hz

Supporting protocol for Foundation Fieldbus

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Nominal output current I2N

2.2A

Max. output voltage

500V

Degree of protection (NEMA)

Other