Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs1
Power consumption75W
Number of digital inputs4
Depth180mm
Number of HW-interfaces parallel0
Width72mm
Number of HW-interfaces USB0
Number of digital outputs0
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
With control elementNo
Height152mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Supporting protocol for LONNo
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Type of converterU converter
Application in industrial area permittedYes
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Application in domestic- and commercial area permittedYes
4-quadrant operation possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for ModbusYes
Number of phases output3
With PC connectionYes
Mains voltage380 - 480V
Integrated breaking resistanceYes
Number of interfaces PROFINET0
Number of phases input3
Supporting protocol for PROFIBUSNo
Max. output frequency400Hz
Degree of protection (IP)IP20
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for PROFINET IONo
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Nominal output current I2N4.3A
Degree of protection (NEMA)Other
Supporting protocol for AS-Interface Safety at WorkNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-344D3EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

1

Power consumption

75W

Number of digital inputs

4

Depth

180mm

Number of HW-interfaces parallel

0

Width

72mm

Number of HW-interfaces USB

0

Number of digital outputs

0

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

With control element

Height

152mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Supporting protocol for LON

Number of HW-interfaces other

0

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Type of converter

U converter

Application in industrial area permitted

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for CAN

Application in domestic- and commercial area permitted

4-quadrant operation possible

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Supporting protocol for Modbus

Number of phases output

3

With PC connection

Mains voltage

380 .. 480V

Integrated breaking resistance

Number of interfaces PROFINET

0

Number of phases input

3

Supporting protocol for PROFIBUS

Max. output frequency

400Hz

Degree of protection (IP)

IP20

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for PROFINET IO

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

4.3A

Degree of protection (NEMA)

Other

Supporting protocol for AS-Interface Safety at Work

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.