Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth180mm
Number of digital outputs0
Height152mm
Width72mm
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of analogue inputs1
Number of HW-interfaces RS-2320
With control elementNo
Number of digital inputs4
Number of HW-interfaces industrial Ethernet0
Power consumption113W
Number of analogue outputs1
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces serial TTY0
With PC connectionYes
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for other bus systemsNo
4-quadrant operation possibleYes
Supporting protocol for SUCONETNo
Mains voltage380 - 480V
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Type of converterU converter
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases output3
Number of phases input3
Supporting protocol for Foundation FieldbusNo
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Nominal output current I2N5.6A
Integrated breaking resistanceYes
Max. output at quadratic load at rated output voltage3kW
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Max. output at linear load at rated output voltage2.2kW
Max. output frequency400Hz
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Relative symmetric net frequency tolerance10%
Max. output voltage500V
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-345D6EB-N20B-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

180mm

Number of digital outputs

0

Height

152mm

Width

72mm

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of analogue inputs

1

Number of HW-interfaces RS-232

0

With control element

Number of digital inputs

4

Number of HW-interfaces industrial Ethernet

0

Power consumption

113W

Number of analogue outputs

1

With optical interface

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

With PC connection

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for DeviceNet

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for other bus systems

4-quadrant operation possible

Supporting protocol for SUCONET

Mains voltage

380 .. 480V

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Type of converter

U converter

Supporting protocol for AS-Interface Safety at Work

Number of phases output

3

Number of phases input

3

Supporting protocol for Foundation Fieldbus

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Application in industrial area permitted

Nominal output current I2N

5.6A

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

3kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Max. output at linear load at rated output voltage

2.2kW

Max. output frequency

400Hz

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Relative symmetric net frequency tolerance

10%

Max. output voltage

500V

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

Other

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.