Height220mm
Width109mm
Supporting protocol for PROFIBUSYes
With control elementYes
Number of HW-interfaces industrial Ethernet1
Number of digital inputs4
Supporting protocol for CANYes
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of digital outputs0
Number of analogue inputs1
Power consumption150W
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for ASINo
Number of analogue outputs1
Depth180mm
Number of HW-interfaces RS-4220
Number of HW-interfaces other1
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Max. output frequency400Hz
Number of phases output3
Number of interfaces PROFINET0
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage3kW
4-quadrant operation possibleYes
Type of converterU converter
Application in domestic- and commercial area permittedYes
Mains frequency50/60 Hz
Integrated breaking resistanceYes
Supporting protocol for EtherNet/IPYes
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage5.5kW
Mains voltage380 - 480V
Nominal output current I2N7.6A
Supporting protocol for BACnetYes
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)Other
Max. output voltage500V
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DM1-347D6EB-S20S-EM

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

220mm

Width

109mm

Supporting protocol for PROFIBUS

With control element

Number of HW-interfaces industrial Ethernet

1

Number of digital inputs

4

Supporting protocol for CAN

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of digital outputs

0

Number of analogue inputs

1

Power consumption

150W

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Number of analogue outputs

1

Depth

180mm

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

1

Number of HW-interfaces parallel

0

Supporting protocol for LON

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

With PC connection

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Max. output frequency

400Hz

Number of phases output

3

Number of interfaces PROFINET

0

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

3kW

4-quadrant operation possible

Type of converter

U converter

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

5.5kW

Mains voltage

380 .. 480V

Nominal output current I2N

7.6A

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

Other

Max. output voltage

500V

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.