  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated operation power at AC-3, 400 V0kW
Number of auxiliary contacts as normally open contact0
Depth225mm
Height500mm
Rated permanent current Iu160A
Width400mm
Conditioned rated short-circuit current Iq100kA
Degree of protection (IP), front sideIP65
Number of poles4
Number of auxiliary contacts as change-over contact0
Rated operating voltage690 - 690V
Version as emergency stop installationYes
InterlockableYes
Type of control elementLong turning handle
Number of switches1
Version as main switchYes
Suitable for floor mountingYes
Suitable for intermediate mountingNo
Suitable for distribution board installationNo
Colour control elementRed
Rated operation power at AC-23, 400 V90kW
Motor drive optionalNo
Voltage release optionalNo
Type of electrical connection of main circuitScrew connection
Max. rated operation voltage Ue AC690V
Version as safety switchYes
Rated short-time withstand current lcw0kA
Version as maintenance-/service switchYes
Motor drive integratedNo
Suitable for front mounting centreNo
Suitable for front mounting 4-holeNo
Rated permanent current at AC-23, 400 V160A
Version as reversing switchNo
Device constructionComplete device in housing
With pre-assembled cablingNo
Degree of protection (NEMA)12
Rated permanent current at AC-21, 400 V160A
Switching power at 400 V90kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DMVS-160/4/SE5/P-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated operation power at AC-3, 400 V

0kW

Number of auxiliary contacts as normally open contact

0

Depth

225mm

Height

500mm

Rated permanent current Iu

160A

Width

400mm

Conditioned rated short-circuit current Iq

100kA

Degree of protection (IP), front side

IP65

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Rated operating voltage

690 .. 690V

Version as emergency stop installation

Interlockable

Type of control element

Long turning handle

Number of switches

1

Version as main switch

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Colour control element

Red

Rated operation power at AC-23, 400 V

90kW

Motor drive optional

Voltage release optional

Type of electrical connection of main circuit

Screw connection

Max. rated operation voltage Ue AC

690V

Version as safety switch

Rated short-time withstand current lcw

0kA

Version as maintenance-/service switch

Motor drive integrated

Suitable for front mounting centre

Suitable for front mounting 4-hole

Rated permanent current at AC-23, 400 V

160A

Version as reversing switch

Device construction

Complete device in housing

With pre-assembled cabling

Degree of protection (NEMA)

12

Rated permanent current at AC-21, 400 V

160A

Switching power at 400 V

90kW

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.