With time switch clockYes
Suitable for safety functionsNo
Number of analogue inputs4
Number of analogue outputs0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4850
Number of HW-interfaces industrial Ethernet1
Supporting protocol for LONNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Explosion safety category for dustNone
Rail mounting possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Explosion safety category for gasNone
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Appendant operation agent (Ex ib)No
Front built-in possibleYes
Wall mounting/direct mountingNo
Supporting protocol for SERCOSNo
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ia)No
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Supporting protocol for PROFINET CBANo
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location class IINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IYes
Supporting protocol for EtherCATNo
Supply voltage AC 60 Hz0 - 0V
SIL according to IEC 61508None
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)Yes
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location division 2Yes
Certified for UL hazardous location group D (propane)Yes
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)Yes
Number of digital inputs4
Number of digital outputs4
Voltage type of supply voltageDC
Degree of protection (IP)IP20
Supply voltage AC 50 Hz0 - 0V
Supply voltage DC20.4 - 28.8V