Aleta.hr

Details

  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • EATON

Technical specifications

Width72mm
Height90mm
With time switch clockYes
Power consumption2W
Number of digital inputs4
ExpandableYes
With displayNo
Suitable for safety functionsNo
Number of analogue inputs4
Depth58mm
Number of analogue outputs0
Switching current0.5A
Voltage type of supply voltageDC
Number of digital outputs4
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4850
Number of HW-interfaces industrial Ethernet1
With optical interfaceNo
Supporting protocol for LONNo
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
With relay outputNo
RedundancyNo
Explosion safety category for dustNone
Rail mounting possibleYes
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusYes
Explosion safety category for gasNone
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Appendant operation agent (Ex ib)No
Front built-in possibleYes
Wall mounting/direct mountingNo
Rack-assembly possibleNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Number of HW-interfaces Wireless0
Appendant operation agent (Ex ia)No
Expansion deviceNo
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Supporting protocol for PROFINET CBANo
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supply voltage AC 50 Hz0 - 0V
IO link masterNo
Supporting protocol for PROFINET IONo
Basic deviceNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location class IINo
Radio standard GSMNo
Radio standard UMTSNo
Certified for UL hazardous location division 1No
Certified for UL hazardous location class IYes
Supporting protocol for EtherCATNo
Radio standard GPRSNo
Supply voltage DC20.4 - 28.8V
Supply voltage AC 60 Hz0 - 0V
SIL according to IEC 61508None
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group C (ethylene)Yes
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location division 2Yes
Certified for UL hazardous location group D (propane)Yes
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group A (acetylene)Yes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EASY-E4-DC-12TCX1P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • EATON

Technical specifications

Width

72mm

Height

90mm

With time switch clock

Power consumption

2W

Number of digital inputs

4

Expandable

With display

Suitable for safety functions

Number of analogue inputs

4

Depth

58mm

Number of analogue outputs

0

Switching current

0.5A

Voltage type of supply voltage

DC

Number of digital outputs

4

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces industrial Ethernet

1

With optical interface

Supporting protocol for LON

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

With relay output

Redundancy

Explosion safety category for dust

None

Rail mounting possible

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Explosion safety category for gas

None

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Appendant operation agent (Ex ib)

Front built-in possible

Wall mounting/direct mounting

Rack-assembly possible

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Number of HW-interfaces Wireless

0

Appendant operation agent (Ex ia)

Expansion device

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Radio standard Wi-Fi 802.11

Radio standard Bluetooth

Supporting protocol for PROFINET CBA

Performance level according to EN ISO 13849-1

None

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supply voltage AC 50 Hz

0 .. 0V

IO link master

Supporting protocol for PROFINET IO

Basic device

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Certified for UL hazardous location class III

Certified for UL hazardous location class II

Radio standard GSM

Radio standard UMTS

Certified for UL hazardous location division 1

Certified for UL hazardous location class I

Supporting protocol for EtherCAT

Radio standard GPRS

Supply voltage DC

20.4 .. 28.8V

Supply voltage AC 60 Hz

0 .. 0V

SIL according to IEC 61508

None

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group G (non-conductive dusts)

Certified for UL hazardous location division 2

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group A (acetylene)

Related products