Details
- •Programmable logic controllers PLC
- •Logic module
- •1 KOM
- •EATON
Technical specifications
Related products
EASY-E4-DC-16TE1P

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- EATON
Technical specifications
Number of digital inputs
8
Suitable for safety functions
Height
90mm
Number of analogue outputs
0
Depth
58mm
With time switch clock
Number of HW-interfaces RS-232
0
Width
72mm
Number of HW-interfaces RS-422
0
Number of digital outputs
8
Voltage type of supply voltage
DC
Switching current
0.5A
Expandable
Power consumption
1W
Number of HW-interfaces industrial Ethernet
0
With display
Supporting protocol for LON
Number of HW-interfaces serial TTY
0
Number of analogue inputs
0
Number of HW-interfaces RS-485
0
Supporting protocol for Modbus
Appendant operation agent (Ex ia)
Explosion safety category for dust
None
Supporting protocol for ASI
Number of HW-interfaces USB
0
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Number of HW-interfaces other
0
Number of HW-interfaces parallel
0
Rail mounting possible
With relay output
Appendant operation agent (Ex ib)
Redundancy
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
With optical interface
Explosion safety category for gas
None
Supporting protocol for CAN
Supporting protocol for other bus systems
Supporting protocol for KNX
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Degree of protection (IP)
IP20
Number of interfaces PROFINET
0
Front built-in possible
Radio standard Wi-Fi 802.11
Supply voltage AC 60 Hz
0 .. 0V
Number of HW-interfaces Wireless
0
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supply voltage DC
20.4 .. 28.8V
Supporting protocol for DeviceNet Safety
Radio standard Bluetooth
Supply voltage AC 50 Hz
0 .. 0V
Performance level according to EN ISO 13849-1
None
IO link master
Basic device
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Rack-assembly possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Expansion device
Wall mounting/direct mounting
Supporting protocol for SafetyBUS p
Radio standard GSM
Radio standard UMTS
Radio standard GPRS
Certified for UL hazardous location class II
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location class I
Certified for UL hazardous location group E (metal dusts)
Supporting protocol for EtherCAT
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location division 2
SIL according to IEC 61508
None
Certified for UL hazardous location division 1
Certified for UL hazardous location class III
Certified for UL hazardous location group G (non-conductive dusts)