Width72mm
ExpandableNo
Power consumption3W
Depth58mm
Switching current5A
Height90mm
With time switch clockNo
Suitable for safety functionsNo
With displayNo
Number of analogue inputs0
Number of analogue outputs0
Number of digital inputs8
Number of digital outputs8
Supporting protocol for LONNo
Voltage type of supply voltageAC/DC
Number of HW-interfaces RS-4220
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Number of HW-interfaces RS-2320
Number of HW-interfaces other0
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusYes
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4850
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPYes
With relay outputYes
Supporting protocol for SUCONETNo
Rail mounting possibleYes
RedundancyNo
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Expansion deviceNo
Degree of protection (IP)IP20
Supporting protocol for EtherNet/IPNo
Explosion safety category for dustNone
Number of interfaces PROFINET0
Wall mounting/direct mountingYes
Radio standard BluetoothNo
Appendant operation agent (Ex ib)No
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Number of HW-interfaces Wireless0
Supporting protocol for DeviceNet SafetyNo
Performance level according to EN ISO 13849-1None
IO link masterNo
Supporting protocol for PROFINET CBANo
Front built-in possibleNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Rack-assembly possibleNo
Basic deviceNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage DC10.2 - 28.8V
SIL according to IEC 61508None
Certified for UL hazardous location group A (acetylene)Yes
Certified for UL hazardous location class IYes
Certified for UL hazardous location group D (propane)Yes
Supply voltage AC 50 Hz85 - 264V
Certified for UL hazardous location class IIINo
Radio standard GPRSNo
Supporting protocol for EtherCATNo
Certified for UL hazardous location group C (ethylene)Yes
Certified for UL hazardous location division 1No
Certified for UL hazardous location group F (carbonaceous dusts)No
Radio standard GSMNo
Certified for UL hazardous location division 2Yes
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group B (hydrogen)No
Supply voltage AC 60 Hz85 - 264V
Certified for UL hazardous location class IINo
Radio standard UMTSNo
Certified for UL hazardous location group G (non-conductive dusts)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

EASY-E4-UC-16RE1P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • EATON

Technical specifications

Width

72mm

Expandable

Power consumption

3W

Depth

58mm

Switching current

5A

Height

90mm

With time switch clock

Suitable for safety functions

With display

Number of analogue inputs

0

Number of analogue outputs

0

Number of digital inputs

8

Number of digital outputs

8

Supporting protocol for LON

Voltage type of supply voltage

AC/DC

Number of HW-interfaces RS-422

0

Number of HW-interfaces industrial Ethernet

0

With optical interface

Number of HW-interfaces RS-232

0

Number of HW-interfaces other

0

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for Modbus

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for Data-Highway

Number of HW-interfaces RS-485

0

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

With relay output

Supporting protocol for SUCONET

Rail mounting possible

Redundancy

Appendant operation agent (Ex ia)

Explosion safety category for gas

None

Expansion device

Degree of protection (IP)

IP20

Supporting protocol for EtherNet/IP

Explosion safety category for dust

None

Number of interfaces PROFINET

0

Wall mounting/direct mounting

Radio standard Bluetooth

Appendant operation agent (Ex ib)

Radio standard Wi-Fi 802.11

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Number of HW-interfaces Wireless

0

Supporting protocol for DeviceNet Safety

Performance level according to EN ISO 13849-1

None

IO link master

Supporting protocol for PROFINET CBA

Front built-in possible

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Rack-assembly possible

Basic device

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supply voltage DC

10.2 .. 28.8V

SIL according to IEC 61508

None

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location class I

Certified for UL hazardous location group D (propane)

Supply voltage AC 50 Hz

85 .. 264V

Certified for UL hazardous location class III

Radio standard GPRS

Supporting protocol for EtherCAT

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location division 1

Certified for UL hazardous location group F (carbonaceous dusts)

Radio standard GSM

Certified for UL hazardous location division 2

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group B (hydrogen)

Supply voltage AC 60 Hz

85 .. 264V

Certified for UL hazardous location class II

Radio standard UMTS

Certified for UL hazardous location group G (non-conductive dusts)