Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Release characteristicB
Rated insulation voltage Ui440V
Voltage typeAC
Built-in depth44mm
Rated current16A
Current limiting class3
Rated voltage230V
Over voltage category3
Pollution degree3
Width in number of modular spacings2
Number of protected poles2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Ambient temperature during operating-25 - 75°C
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-B16/2-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Release characteristic

B

Rated insulation voltage Ui

440V

Voltage type

AC

Built-in depth

44mm

Rated current

16A

Current limiting class

3

Rated voltage

230V

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

2

Number of protected poles

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 .. 75°C

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.