  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Built-in depth44mm
Pollution degree3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Over voltage category3
Width in number of modular spacings2
Current limiting class3
Release characteristicB
Degree of protection (IP)IP20
Number of protected poles2
Rated voltage230V
Rated current40A
Number of poles (total)2
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-B40/2-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Built-in depth

44mm

Pollution degree

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Over voltage category

3

Width in number of modular spacings

2

Current limiting class

3

Release characteristic

B

Degree of protection (IP)

IP20

Number of protected poles

2

Rated voltage

230V

Rated current

40A

Number of poles (total)

2

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA