  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Release characteristicB
Rated voltage230V
Built-in depth69.5mm
Rated insulation voltage Ui500V
Width in number of modular spacings2
Current limiting class3
Degree of protection (IP)IP20
Frequency50 Hz
Surge current capacity0.25kA
Pollution degree2
Over voltage category3
Number of protected poles1
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 610096kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-20kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Rated current13A
Rated fault current0.03A
Leakage current typeA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-B13/1N/003-A-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Release characteristic

B

Rated voltage

230V

Built-in depth

69.5mm

Rated insulation voltage Ui

500V

Width in number of modular spacings

2

Current limiting class

3

Degree of protection (IP)

IP20

Frequency

50 Hz

Surge current capacity

0.25kA

Pollution degree

2

Over voltage category

3

Number of protected poles

1

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

6kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Rated current

13A

Rated fault current

0.03A

Leakage current type

A

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.