  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage230V
Rated current16A
Release characteristicB
Built-in depth69.5mm
Voltage typeAC
Rated fault current0.03A
Surge current capacity0.25kA
Current limiting class3
Leakage current typeA
Over voltage category3
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity according to IEC 60947-20kA
Number of protected poles1
Frequency50 Hz
Pollution degree2
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Number of poles (total)2
Ambient temperature during operating-25 - 40°C
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-B16/1N/003-A-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

230V

Rated current

16A

Release characteristic

B

Built-in depth

69.5mm

Voltage type

AC

Rated fault current

0.03A

Surge current capacity

0.25kA

Current limiting class

3

Leakage current type

A

Over voltage category

3

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Number of protected poles

1

Frequency

50 Hz

Pollution degree

2

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Number of poles (total)

2

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA