Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui500V
Rated current6A
Over voltage category3
Rated voltage230V
Voltage typeAC
Release characteristicC
Degree of protection (IP)IP20
Frequency50 Hz
Suitable for flush-mounted installationNo
Built-in depth69.5mm
Current limiting class3
Rated short-circuit breaking capacity according to IEC 60947-20kA
Width in number of modular spacings2
Pollution degree2
Number of protected poles1
Surge current capacity0.25kA
Rated fault current0.03A
Leakage current typeAC
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-C6/1N/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

500V

Rated current

6A

Over voltage category

3

Rated voltage

230V

Voltage type

AC

Release characteristic

C

Degree of protection (IP)

IP20

Frequency

50 Hz

Suitable for flush-mounted installation

Built-in depth

69.5mm

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Width in number of modular spacings

2

Pollution degree

2

Number of protected poles

1

Surge current capacity

0.25kA

Rated fault current

0.03A

Leakage current type

AC

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.