  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current0.03A
Rated current6A
Rated insulation voltage Ui500V
Voltage typeAC
Rated voltage230V
Built-in depth69.5mm
Release characteristicC
Over voltage category3
Concurrently switching neutral conductorYes
Leakage current typeA
Degree of protection (IP)IP20
Current limiting class3
Surge current capacity0.25kA
Width in number of modular spacings2
Connectable conductor cross section solid-core1 - 25mm²
Suitable for flush-mounted installationNo
Number of protected poles1
Frequency50 Hz
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HNB-C6/1N/003-A-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated fault current

0.03A

Rated current

6A

Rated insulation voltage Ui

500V

Voltage type

AC

Rated voltage

230V

Built-in depth

69.5mm

Release characteristic

C

Over voltage category

3

Concurrently switching neutral conductor

Leakage current type

A

Degree of protection (IP)

IP20

Current limiting class

3

Surge current capacity

0.25kA

Width in number of modular spacings

2

Connectable conductor cross section solid-core

1 .. 25mm²

Suitable for flush-mounted installation

Number of protected poles

1

Frequency

50 Hz

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.