Technical specifications

Over voltage category3
Current limiting class3
Release characteristicC
Rated current16A
Frequency50 - 60Hz
Pollution degree3
Built-in depth44mm
Voltage typeAC
Width in number of modular spacings2
Rated voltage230V
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-C16/2-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Over voltage category

3

Current limiting class

3

Release characteristic

C

Rated current

16A

Frequency

50 .. 60Hz

Pollution degree

3

Built-in depth

44mm

Voltage type

AC

Width in number of modular spacings

2

Rated voltage

230V

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV