Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Built-in depth44mm
Rated voltage230V
Voltage typeAC
Degree of protection (IP)IP20
Over voltage category3
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Number of protected poles3
Pollution degree3
Concurrently switching neutral conductorNo
Number of poles (total)4
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationYes
Ambient temperature during operating-25 - 75°C
Release characteristicC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

HN-C40/3N-HX

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Built-in depth

44mm

Rated voltage

230V

Voltage type

AC

Degree of protection (IP)

IP20

Over voltage category

3

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Number of protected poles

3

Pollution degree

3

Concurrently switching neutral conductor

Number of poles (total)

4

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.