Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated operating voltage
690 - 690V
Version as emergency stop installation
Yes
Rated permanent current Iu
32A
Version as reversing switch
No
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Yes
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-3, 400 V
13kW
Rated short-time withstand current lcw
0.64kA
Number of switches
1
Number of auxiliary contacts as normally open contact
1
Rated operation power at AC-23, 400 V
15kW
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Conditioned rated short-circuit current Iq
80kA
Number of auxiliary contacts as normally closed contact
1
Switching power at 400 V
15kW
Motor drive optional
No
Voltage release optional
No
Suitable for front mounting centre
No
Motor drive integrated
No
Suitable for intermediate mounting
No
Version as main switch
Yes
Suitable for distribution board installation
No
Suitable for front mounting 4-hole
No
Type of control element
Door coupling rotary drive
Suitable for floor mounting
Yes
Rated permanent current at AC-21, 400 V
32A
Colour control element
Red
Version as safety switch
Yes
Device construction
Complete device in housing
Degree of protection (NEMA)
12
Depth
200mm
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Degree of protection (IP), front side
IP65
With pre-assembled cabling
No
Width
150mm
Height
135mm
P1-32/SE1/SVB/HI11

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Rated permanent current Iu
32A
Version as reversing switch
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-3, 400 V
13kW
Rated short-time withstand current lcw
0.64kA
Number of switches
1
Number of auxiliary contacts as normally open contact
1
Rated operation power at AC-23, 400 V
15kW
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Conditioned rated short-circuit current Iq
80kA
Number of auxiliary contacts as normally closed contact
1
Switching power at 400 V
15kW
Motor drive optional
Voltage release optional
Suitable for front mounting centre
Motor drive integrated
Suitable for intermediate mounting
Version as main switch
Suitable for distribution board installation
Suitable for front mounting 4-hole
Type of control element
Door coupling rotary drive
Suitable for floor mounting
Rated permanent current at AC-21, 400 V
32A
Colour control element
Red
Version as safety switch
Device construction
Complete device in housing
Degree of protection (NEMA)
12
Depth
200mm
Type of electrical connection of main circuit
Screw connection
Interlockable
Degree of protection (IP), front side
IP65
With pre-assembled cabling
Width
150mm
Height
135mm
We use cookies to enhance your experience.