Technical specifications

Number of digital outputs1
Height214mm
With control elementNo
Number of digital inputs6
Depth419mm
Number of analogue inputs2
Width144mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Number of analogue outputs1
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Supporting protocol for ASINo
With PC connectionNo
Supporting protocol for Data-HighwayNo
With optical interfaceNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Degree of protection (IP)IP21
Number of phases output3
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Type of converterOther
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Mains voltage380 - 500V
4-quadrant operation possibleNo
Application in domestic- and commercial area permittedNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage15kW
Integrated breaking resistanceNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Max. output frequency320Hz
Application in industrial area permittedNo
Supporting protocol for EtherNet/IPNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Max. output at linear load at rated output voltage11kW
Supporting protocol for PROFIsafeNo
Number of phases input3
Degree of protection (NEMA)Other
Max. output voltage500V
Supporting protocol for BACnetNo
Nominal output current I2N31A
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX015A1-4A1B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital outputs

1

Height

214mm

With control element

Number of digital inputs

6

Depth

419mm

Number of analogue inputs

2

Width

144mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Number of analogue outputs

1

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Supporting protocol for ASI

With PC connection

Supporting protocol for Data-Highway

With optical interface

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for TCP/IP

Degree of protection (IP)

IP21

Number of phases output

3

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Type of converter

Other

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Mains voltage

380 .. 500V

4-quadrant operation possible

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

15kW

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Max. output frequency

320Hz

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Max. output at linear load at rated output voltage

11kW

Supporting protocol for PROFIsafe

Number of phases input

3

Degree of protection (NEMA)

Other

Max. output voltage

500V

Supporting protocol for BACnet

Nominal output current I2N

31A

Supporting protocol for SafetyBUS p

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.