Technical specifications

With control elementNo
Number of analogue inputs2
Depth640mm
Width237mm
Number of HW-interfaces other0
Number of HW-interfaces RS-4850
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Height257mm
Number of HW-interfaces RS-2321
Number of analogue outputs1
Number of digital outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of digital inputs6
Number of HW-interfaces USB0
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
With optical interfaceNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of phases input3
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Number of phases output3
With PC connectionNo
Mains voltage525 - 690V
Degree of protection (IP)IP21
Supporting protocol for SERCOSNo
Integrated breaking resistanceNo
Type of converterOther
Application in industrial area permittedNo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Max. output at quadratic load at rated output voltage37kW
Application in domestic- and commercial area permittedNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Max. output voltage690V
Max. output at linear load at rated output voltage30kW
Max. output frequency320Hz
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Nominal output current I2N41A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX030A1-5A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Number of analogue inputs

2

Depth

640mm

Width

237mm

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

0

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Height

257mm

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

Number of digital outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of digital inputs

6

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for SUCONET

With optical interface

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of phases input

3

Number of interfaces PROFINET

0

4-quadrant operation possible

Number of phases output

3

With PC connection

Mains voltage

525 .. 690V

Degree of protection (IP)

IP21

Supporting protocol for SERCOS

Integrated breaking resistance

Type of converter

Other

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Max. output at quadratic load at rated output voltage

37kW

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Max. output voltage

690V

Max. output at linear load at rated output voltage

30kW

Max. output frequency

320Hz

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Nominal output current I2N

41A