Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width237mm
Number of HW-interfaces serial TTY0
Number of analogue inputs2
Supporting protocol for CANNo
Number of analogue outputs1
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of HW-interfaces other0
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Height257mm
Number of digital outputs1
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-2321
Supporting protocol for ASINo
Supporting protocol for KNXNo
Number of digital inputs6
With control elementNo
Depth640mm
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP21
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
Integrated breaking resistanceNo
Relative symmetric net frequency tolerance10%
Max. output frequency320Hz
Supporting protocol for DeviceNetNo
Number of phases input3
Supporting protocol for other bus systemsNo
Mains voltage380 - 500V
Relative symmetric net voltage tolerance10%
Number of phases output3
Application in domestic- and commercial area permittedNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage37kW
Max. output at linear load at rated output voltage30kW
Application in industrial area permittedNo
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Type of converterOther
Supporting protocol for Data-HighwayNo
With PC connectionNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Nominal output current I2N72A
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Supporting protocol for Foundation FieldbusNo
Supporting protocol for BACnetNo
Max. output voltage500V
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX040A1-4A1N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

237mm

Number of HW-interfaces serial TTY

0

Number of analogue inputs

2

Supporting protocol for CAN

Number of analogue outputs

1

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces other

0

With optical interface

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Height

257mm

Number of digital outputs

1

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-232

1

Supporting protocol for ASI

Supporting protocol for KNX

Number of digital inputs

6

With control element

Depth

640mm

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP21

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

Integrated breaking resistance

Relative symmetric net frequency tolerance

10%

Max. output frequency

320Hz

Supporting protocol for DeviceNet

Number of phases input

3

Supporting protocol for other bus systems

Mains voltage

380 .. 500V

Relative symmetric net voltage tolerance

10%

Number of phases output

3

Application in domestic- and commercial area permitted

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

37kW

Max. output at linear load at rated output voltage

30kW

Application in industrial area permitted

Number of interfaces PROFINET

0

4-quadrant operation possible

Type of converter

Other

Supporting protocol for Data-Highway

With PC connection

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Nominal output current I2N

72A

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Supporting protocol for Foundation Fieldbus

Supporting protocol for BACnet

Max. output voltage

500V

Supporting protocol for PROFINET IO

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.