Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width237mm
With control elementYes
Supporting protocol for ModbusYes
Depth189mm
Number of HW-interfaces serial TTY0
Number of analogue outputs1
Number of HW-interfaces USB0
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet0
Number of analogue inputs2
Number of HW-interfaces RS-4850
Supporting protocol for LONYes
Number of HW-interfaces RS-4220
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Height630mm
Number of digital inputs6
Supporting protocol for INTERBUSNo
Number of digital outputs1
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayYes
Supporting protocol for SERCOSNo
With PC connectionYes
Supporting protocol for SUCONETNo
Type of converterU converter
Integrated breaking resistanceYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Number of phases input3
Supporting protocol for DeviceNetYes
4-quadrant operation possibleYes
Number of interfaces PROFINET0
Number of phases output3
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Mains voltage323 - 550V
Degree of protection (IP)IP54
Mains frequency50/60 Hz
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage45kW
Supporting protocol for DeviceNet SafetyNo
Max. output at linear load at rated output voltage37kW
Relative symmetric net voltage tolerance10%
Max. output frequency320Hz
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Nominal output current I2N87A
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX050A2-4A1B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

237mm

With control element

Supporting protocol for Modbus

Depth

189mm

Number of HW-interfaces serial TTY

0

Number of analogue outputs

1

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

0

Number of analogue inputs

2

Number of HW-interfaces RS-485

0

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Supporting protocol for CAN

Supporting protocol for TCP/IP

Height

630mm

Number of digital inputs

6

Supporting protocol for INTERBUS

Number of digital outputs

1

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

With PC connection

Supporting protocol for SUCONET

Type of converter

U converter

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Number of phases input

3

Supporting protocol for DeviceNet

4-quadrant operation possible

Number of interfaces PROFINET

0

Number of phases output

3

Application in domestic- and commercial area permitted

Application in industrial area permitted

Mains voltage

323 .. 550V

Degree of protection (IP)

IP54

Mains frequency

50/60 Hz

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

45kW

Supporting protocol for DeviceNet Safety

Max. output at linear load at rated output voltage

37kW

Relative symmetric net voltage tolerance

10%

Max. output frequency

320Hz

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Nominal output current I2N

87A

Degree of protection (NEMA)

12

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.