Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementYes
Width291mm
Depth344mm
Number of digital outputs1
Number of digital inputs6
Height758mm
Supporting protocol for LONYes
Number of HW-interfaces RS-2321
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
Number of analogue inputs2
Supporting protocol for ASINo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of HW-interfaces other0
With optical interfaceNo
Mains voltage323 - 550V
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Supporting protocol for Data-HighwayYes
With PC connectionYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP21
Supporting protocol for PROFIBUSYes
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
4-quadrant operation possibleYes
Mains frequency50/60 Hz
Supporting protocol for EtherNet/IPYes
Supporting protocol for DeviceNet SafetyNo
Number of phases output3
Type of converterU converter
Application in domestic- and commercial area permittedYes
Number of interfaces PROFINET0
Max. output at linear load at rated output voltage75kW
Max. output at quadratic load at rated output voltage90kW
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Application in industrial area permittedYes
Relative symmetric net frequency tolerance10%
Max. output frequency320Hz
Integrated breaking resistanceYes
Supporting protocol for Foundation FieldbusNo
Number of phases input3
Max. output voltage500V
Degree of protection (NEMA)1
Nominal output current I2N170A
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX100A1-4A1B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Width

291mm

Depth

344mm

Number of digital outputs

1

Number of digital inputs

6

Height

758mm

Supporting protocol for LON

Number of HW-interfaces RS-232

1

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

Number of analogue inputs

2

Supporting protocol for ASI

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

0

With optical interface

Mains voltage

323 .. 550V

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for Data-Highway

With PC connection

Supporting protocol for KNX

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Degree of protection (IP)

IP21

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Number of phases output

3

Type of converter

U converter

Application in domestic- and commercial area permitted

Number of interfaces PROFINET

0

Max. output at linear load at rated output voltage

75kW

Max. output at quadratic load at rated output voltage

90kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Application in industrial area permitted

Relative symmetric net frequency tolerance

10%

Max. output frequency

320Hz

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Number of phases input

3

Max. output voltage

500V

Degree of protection (NEMA)

1

Nominal output current I2N

170A

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.