Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementNo
Height344mm
Width291mm
Depth758mm
Number of digital inputs6
Number of analogue outputs1
Supporting protocol for PROFIBUSNo
Number of digital outputs1
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4850
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2321
Number of HW-interfaces parallel0
With optical interfaceNo
Number of analogue inputs2
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ASINo
Number of HW-interfaces other0
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP21
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
With PC connectionNo
Type of converterOther
Max. output at quadratic load at rated output voltage90kW
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Integrated breaking resistanceNo
Number of phases input3
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Application in industrial area permittedNo
Max. output frequency320Hz
Supporting protocol for SERCOSNo
Application in domestic- and commercial area permittedNo
Max. output at linear load at rated output voltage75kW
Mains voltage380 - 500V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N170A
Supporting protocol for BACnetNo
Max. output voltage500V
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX100A1-4A1N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Height

344mm

Width

291mm

Depth

758mm

Number of digital inputs

6

Number of analogue outputs

1

Supporting protocol for PROFIBUS

Number of digital outputs

1

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

0

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces parallel

0

With optical interface

Number of analogue inputs

2

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for ASI

Number of HW-interfaces other

0

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Degree of protection (IP)

IP21

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for CAN

With PC connection

Type of converter

Other

Max. output at quadratic load at rated output voltage

90kW

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

4-quadrant operation possible

Integrated breaking resistance

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Application in industrial area permitted

Max. output frequency

320Hz

Supporting protocol for SERCOS

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

75kW

Mains voltage

380 .. 500V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Nominal output current I2N

170A

Supporting protocol for BACnet

Max. output voltage

500V

Degree of protection (NEMA)

Other

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.