Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Number of digital inputs6
Number of analogue outputs1
Number of digital outputs1
Supporting protocol for LONYes
Number of HW-interfaces industrial Ethernet0
Height758mm
Width291mm
Depth344mm
With control elementYes
Number of HW-interfaces other0
Supporting protocol for ModbusYes
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2321
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces RS-4850
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSYes
Supporting protocol for KNXNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for Data-HighwayYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
With PC connectionYes
Supporting protocol for SERCOSNo
Mains voltage323 - 550V
Degree of protection (IP)IP54
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleYes
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage90kW
Number of interfaces PROFINET0
Max. output frequency320Hz
Number of phases output3
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Type of converterU converter
Max. output at linear load at rated output voltage75kW
Integrated breaking resistanceYes
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)12
Nominal output current I2N170A
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Max. output voltage500V
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IOYes
Number of phases input3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX100A2-4A1B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Number of digital inputs

6

Number of analogue outputs

1

Number of digital outputs

1

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Height

758mm

Width

291mm

Depth

344mm

With control element

Number of HW-interfaces other

0

Supporting protocol for Modbus

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces RS-485

0

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

With PC connection

Supporting protocol for SERCOS

Mains voltage

323 .. 550V

Degree of protection (IP)

IP54

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

90kW

Number of interfaces PROFINET

0

Max. output frequency

320Hz

Number of phases output

3

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Max. output at linear load at rated output voltage

75kW

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Degree of protection (NEMA)

12

Nominal output current I2N

170A

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Max. output voltage

500V

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Number of phases input

3

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.