Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Width291mm
Depth758mm
Supporting protocol for LONNo
Number of HW-interfaces other0
Number of digital outputs1
Number of digital inputs6
Number of HW-interfaces USB0
Number of HW-interfaces RS-2321
Number of analogue outputs1
Number of HW-interfaces parallel0
Height344mm
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4220
Number of analogue inputs2
Number of HW-interfaces RS-4850
With control elementNo
Number of phases input3
Max. output frequency320Hz
Supporting protocol for DeviceNetNo
Mains voltage380 - 500V
Number of phases output3
Number of interfaces PROFINET0
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Application in domestic- and commercial area permittedNo
Supporting protocol for CANNo
Supporting protocol for SERCOSNo
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Degree of protection (IP)IP54
Supporting protocol for KNXNo
Type of converterOther
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Integrated breaking resistanceNo
Supporting protocol for Data-HighwayNo
Application in industrial area permittedNo
With PC connectionNo
Max. output at linear load at rated output voltage90kW
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage110kW
Supporting protocol for PROFIsafeNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage500V
Supporting protocol for EtherNet/IPNo
Nominal output current I2N205A
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX125A2-4A1N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces industrial Ethernet

0

With optical interface

Width

291mm

Depth

758mm

Supporting protocol for LON

Number of HW-interfaces other

0

Number of digital outputs

1

Number of digital inputs

6

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

Number of HW-interfaces parallel

0

Height

344mm

Supporting protocol for TCP/IP

Number of HW-interfaces RS-422

0

Number of analogue inputs

2

Number of HW-interfaces RS-485

0

With control element

Number of phases input

3

Max. output frequency

320Hz

Supporting protocol for DeviceNet

Mains voltage

380 .. 500V

Number of phases output

3

Number of interfaces PROFINET

0

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for Modbus

Application in domestic- and commercial area permitted

Supporting protocol for CAN

Supporting protocol for SERCOS

4-quadrant operation possible

Mains frequency

50/60 Hz

Degree of protection (IP)

IP54

Supporting protocol for KNX

Type of converter

Other

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Integrated breaking resistance

Supporting protocol for Data-Highway

Application in industrial area permitted

With PC connection

Max. output at linear load at rated output voltage

90kW

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

110kW

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Max. output voltage

500V

Supporting protocol for EtherNet/IP

Nominal output current I2N

205A

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.