  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other0
Number of HW-interfaces RS-2321
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces USB0
With control elementNo
Number of HW-interfaces parallel0
Number of digital inputs6
Height362mm
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Depth1150mm
Width480mm
Number of digital outputs1
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for PROFIBUSNo
Number of analogue inputs2
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Degree of protection (IP)IP21
Supporting protocol for other bus systemsNo
Supporting protocol for SERCOSNo
Supporting protocol for ModbusNo
With PC connectionNo
Max. output at quadratic load at rated output voltage200kW
Max. output frequency320Hz
Application in domestic- and commercial area permittedNo
Application in industrial area permittedNo
Type of converterOther
Number of phases output3
Number of interfaces PROFINET0
Integrated breaking resistanceNo
Mains frequency50/60 Hz
Max. output at linear load at rated output voltage160kW
4-quadrant operation possibleNo
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
Relative symmetric net voltage tolerance10%
Mains voltage525 - 690V
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Relative symmetric net frequency tolerance10%
Supporting protocol for SafetyBUS pNo
Max. output voltage690V
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Nominal output current I2N208A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX175A1-5A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

1

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Number of HW-interfaces USB

0

With control element

Number of HW-interfaces parallel

0

Number of digital inputs

6

Height

362mm

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Depth

1150mm

Width

480mm

Number of digital outputs

1

Supporting protocol for TCP/IP

Supporting protocol for ASI

With optical interface

Supporting protocol for PROFIBUS

Number of analogue inputs

2

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Degree of protection (IP)

IP21

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for Modbus

With PC connection

Max. output at quadratic load at rated output voltage

200kW

Max. output frequency

320Hz

Application in domestic- and commercial area permitted

Application in industrial area permitted

Type of converter

Other

Number of phases output

3

Number of interfaces PROFINET

0

Integrated breaking resistance

Mains frequency

50/60 Hz

Max. output at linear load at rated output voltage

160kW

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Mains voltage

525 .. 690V

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Relative symmetric net frequency tolerance

10%

Supporting protocol for SafetyBUS p

Max. output voltage

690V

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

208A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.