Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth362mm
Height1150mm
With control elementYes
Number of digital inputs6
Number of digital outputs1
Width480mm
Number of analogue outputs1
Supporting protocol for PROFIBUSYes
Number of analogue inputs2
Degree of protection (IP)IP21
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for DeviceNetYes
Supporting protocol for KNXNo
Number of HW-interfaces serial TTY0
Supporting protocol for LONYes
Number of HW-interfaces RS-4220
Supporting protocol for Data-HighwayYes
Number of HW-interfaces USB0
Number of HW-interfaces other0
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4850
With PC connectionYes
Supporting protocol for ASINo
Number of HW-interfaces RS-2321
Supporting protocol for other bus systemsYes
Application in domestic- and commercial area permittedYes
Supporting protocol for INTERBUS-SafetyNo
Number of phases input3
Type of converterU converter
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Max. output at linear load at rated output voltage132kW
Supporting protocol for Foundation FieldbusNo
Max. output frequency320Hz
Supporting protocol for PROFIsafeNo
Mains frequency50/60 Hz
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceYes
Number of phases output3
Supporting protocol for PROFINET IOYes
4-quadrant operation possibleYes
Supporting protocol for DeviceNet SafetyNo
Max. output at quadratic load at rated output voltage160kW
Supporting protocol for SafetyBUS pNo
Application in industrial area permittedYes
Supporting protocol for EtherNet/IPYes
Mains voltage323 - 550V
Number of interfaces PROFINET0
Degree of protection (NEMA)1
Max. output voltage500V
Supporting protocol for BACnetNo
Nominal output current I2N300A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX200A1-4A1B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Depth

362mm

Height

1150mm

With control element

Number of digital inputs

6

Number of digital outputs

1

Width

480mm

Number of analogue outputs

1

Supporting protocol for PROFIBUS

Number of analogue inputs

2

Degree of protection (IP)

IP21

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Modbus

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for DeviceNet

Supporting protocol for KNX

Number of HW-interfaces serial TTY

0

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Supporting protocol for Data-Highway

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for SUCONET

Number of HW-interfaces RS-485

0

With PC connection

Supporting protocol for ASI

Number of HW-interfaces RS-232

1

Supporting protocol for other bus systems

Application in domestic- and commercial area permitted

Supporting protocol for INTERBUS-Safety

Number of phases input

3

Type of converter

U converter

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Max. output at linear load at rated output voltage

132kW

Supporting protocol for Foundation Fieldbus

Max. output frequency

320Hz

Supporting protocol for PROFIsafe

Mains frequency

50/60 Hz

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Number of phases output

3

Supporting protocol for PROFINET IO

4-quadrant operation possible

Supporting protocol for DeviceNet Safety

Max. output at quadratic load at rated output voltage

160kW

Supporting protocol for SafetyBUS p

Application in industrial area permitted

Supporting protocol for EtherNet/IP

Mains voltage

323 .. 550V

Number of interfaces PROFINET

0

Degree of protection (NEMA)

1

Max. output voltage

500V

Supporting protocol for BACnet

Nominal output current I2N

300A

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.