Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs2
Width595mm
Number of HW-interfaces RS-4220
Supporting protocol for LONYes
Number of HW-interfaces serial TTY0
With control elementYes
Number of HW-interfaces RS-2321
Number of HW-interfaces USB0
Height2018mm
Number of digital outputs1
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4850
Number of digital inputs6
Depth602mm
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of HW-interfaces other0
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for other bus systemsYes
Supporting protocol for ASINo
Type of converterU converter
Mains frequency50/60 Hz
4-quadrant operation possibleYes
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Degree of protection (IP)IP21
With PC connectionYes
Number of interfaces PROFINET0
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayYes
Mains voltage447 - 759V
Max. output frequency320Hz
Application in domestic- and commercial area permittedYes
Number of phases output3
Application in industrial area permittedYes
Number of phases input3
Integrated breaking resistanceNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage200kW
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output at quadratic load at rated output voltage250kW
Relative symmetric net frequency tolerance10%
Supporting protocol for BACnetNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET IOYes
Degree of protection (NEMA)1
Nominal output current I2N261A
Supporting protocol for PROFIsafeNo
Max. output voltage690V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX200A1-5A4N1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of analogue inputs

2

Width

595mm

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

With control element

Number of HW-interfaces RS-232

1

Number of HW-interfaces USB

0

Height

2018mm

Number of digital outputs

1

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Number of digital inputs

6

Depth

602mm

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Supporting protocol for ASI

Type of converter

U converter

Mains frequency

50/60 Hz

4-quadrant operation possible

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Degree of protection (IP)

IP21

With PC connection

Number of interfaces PROFINET

0

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Mains voltage

447 .. 759V

Max. output frequency

320Hz

Application in domestic- and commercial area permitted

Number of phases output

3

Application in industrial area permitted

Number of phases input

3

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

200kW

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Max. output at quadratic load at rated output voltage

250kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for BACnet

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET IO

Degree of protection (NEMA)

1

Nominal output current I2N

261A

Supporting protocol for PROFIsafe

Max. output voltage

690V

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.