Height1165mm
Width500mm
Depth506mm
Number of digital outputs1
Number of digital inputs6
With control elementYes
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of analogue outputs1
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other0
Supporting protocol for CANYes
Number of HW-interfaces RS-2321
Number of HW-interfaces USB0
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for LONYes
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPYes
Supporting protocol for Data-HighwayYes
With optical interfaceNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Supporting protocol for PROFIBUSYes
Number of analogue inputs2
With PC connectionYes
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP00
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Integrated breaking resistanceYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Number of phases output3
Number of interfaces PROFINET0
Mains voltage323 - 550V
Type of converterU converter
Max. output at quadratic load at rated output voltage200kW
Relative symmetric net voltage tolerance10%
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Number of phases input3
Supporting protocol for AS-Interface Safety at WorkNo
4-quadrant operation possibleYes
Max. output at linear load at rated output voltage160kW
Relative symmetric net frequency tolerance10%
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Application in domestic- and commercial area permittedYes
Application in industrial area permittedYes
Supporting protocol for PROFIsafeNo
Max. output frequency320Hz
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N385A
Degree of protection (NEMA)Other
Max. output voltage500V
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SPX250A0-4A2B1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

1165mm

Width

500mm

Depth

506mm

Number of digital outputs

1

Number of digital inputs

6

With control element

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of analogue outputs

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

0

Supporting protocol for CAN

Number of HW-interfaces RS-232

1

Number of HW-interfaces USB

0

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for LON

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

With optical interface

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Supporting protocol for PROFIBUS

Number of analogue inputs

2

With PC connection

Supporting protocol for DeviceNet

Degree of protection (IP)

IP00

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for KNX

Integrated breaking resistance

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Number of phases output

3

Number of interfaces PROFINET

0

Mains voltage

323 .. 550V

Type of converter

U converter

Max. output at quadratic load at rated output voltage

200kW

Relative symmetric net voltage tolerance

10%

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Number of phases input

3

Supporting protocol for AS-Interface Safety at Work

4-quadrant operation possible

Max. output at linear load at rated output voltage

160kW

Relative symmetric net frequency tolerance

10%

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Application in domestic- and commercial area permitted

Application in industrial area permitted

Supporting protocol for PROFIsafe

Max. output frequency

320Hz

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

385A

Degree of protection (NEMA)

Other

Max. output voltage

500V